德国原装进口贺利氏古莎·泰克诺维Heraeus Kulzer Technovit 9100 Embedding Kits包埋树脂试剂盒(64715444)
聚合反应不能有氧的参与,一般在过氧化物/胺的催化下进行。加某些成分如PMMA粉和调剂可以在–8至–20℃时聚合,当然,一定保证聚合热量的及时散发。在上述温度范围内聚合的话,体积控制在3-15ml,则聚合时间为18到24小时。适用于组织样品制备、染色、免疫化学、酶组织学检、原位杂交等技术中。
基质是甲基丙烯酸甲酯,可以包埋矿石等样品(对于软组织块同样适用)用于染色等。
应用领域:
• 用于骨组织的包埋和切片,例如盆骨的活组织检测、低密度骨样品和高密度骨样品检测等
• 对样品切磨和显微打磨(与点技术联合),例如下颌和牙齿的有或无植入物分割。
Heraeus Kulzer Technovit 9100 Embedding Kits 64715444
Technovit 9100 is a plastic embedding system based on MMA (Methyl methracrylate).
Technovit 9100 is used in medicine, botany and zoology.
Technovit 9100 was specifically developed for the embedding of mineralised tissues as well as soft tissue with an
expanded study spectrum in light microscopy.
The deplasticized sections are suitable for histological overview staining, enzyme chemistry and immunohistological
studies, including in-situ hybridisation.
Thin sections for immunohistology can be stuck to glass object holders and deplasticized.
Fields of application
Hard-cutting technique for making thin layers
Examples: Iliac crest biopsies, smaller, spongy and compact bone tissue specimens
Division thin section technique (division procedure in point contact technology)
Examples: Tooth/jaw areas with and without implants, non-cemented endoprostheses with shaft bones
Combined division-thin section technique and hard-cutting technique (target preparation)
Examples: Boundary layer and environment assessment for metal implants and non-cemented endoprostheses
Tissues that cannot be cut are teeth-bearing jaw sections with fillings, crowns and bridges, thick corticalis, implant-bearing (metal or ceramic) jaw or long bones, or brittle, hypermineralised bones.
Material properties
Polymerisation of the hydrophobic Technovit® 9100 occurs by excluding oxygen using a catalyst system made of peroxide
and amine. Additional components such as PMMA powder and regulator allow for a controlled polymerisation in the cold
(in the range of -2 to -20 °C, depending on the volume) that guarantees complete dissipation of the polymerisation heat.
The benefits of the system at a glance
• Polymerisation below freezing
• Reproducibility of the embedding results and reliability due to constant, documented quality controls
• Equal block hardening
• The PMMA block remains transparent
• Better results with regard to cutting and staining because Technovit® 9100 contains a hydrophilising agent
• Can be used for thin section and the sawing and cutting techniques
• Enzyme histology and immunohistology as well as in-situ hybridisation possible (sections)
Item No. |
Designation |
Quantity |
64715444 |
Technovit® 9100 Combipack |
1 x 1000 ml basic solution 1 x 120 g PMMA powder 8 x 1 g hardener 1 1 x 10 ml hardener 2 1 x 5 ml regulator |
66006735 |
Technovit 9100 basic solution |
5000 ml |
66010251 |
Technovit 9100 PMMA powder |
1000 g |
64709022 |
Technovit 9100 hardener 1 |
100 x 1 g |
66039185 |
Technovit 9100 hardener 2 |
9 x 10 ml |
66039184 |
Technovit 9100 regulator |
12 x 5 ml |
Heraeus Kulzer GmbH (Made In Germany) |